MEASURING PRINCIPLE
The measuring unit adopts the principle of infrared scattering which is used in the international field.
The sensors receive the light scattered andpenetrated by oil droplets in the oily water when the infrared transmit the flowing oily water and then the output signal is transmitted to CPU to be processed after being handled by amplifier, filter and A/D transmitter.
FEATURES
(1) High accuracy with advanced principle of infrared ray measurement and microprocessor technology
(2) The separation of control unit and measuring unit increases the stability and reliability of the instrument and also causes the convenience for maintenance and cleaning of the measuring unit.
(3) Most clear display of LCD shows the time,oil content, system running status all the time.
(4) The real-time data is saved automatically and can be read whenever you need.
(5) With the function of system failure alarm and self-checking.
TECHNOLOGY INDEX
→ Measuring range:0~50ppm
→ Accuracy:±5ppm meet MEPC.107(49)
→ Alarm point 1、2:can be adjust from 0 to 15ppm(it is set at15 ppm in factory)
→ Alarm point 1(annunciation purpose):the delay time can be adjusted between 0 - 120 seconds.(it is set for 2 seconds in the factory),red LED indicator.
→ Alarm point 2(control purpose):the delay time can be adjusted between 0 - 120 seconds.(it is set for 15 seconds in the factory),red LED indicator.
→ Alarm output:potential free contacts; Contact rating: 3A/250V
→ Sample water pressure: 0.1~10bar
→ Power supply:110V/220V ±10%
→ Ambient temperature and humidity: temperature:0℃~55℃ humidity: <95%
→ Degree of protection:IP65
|
 |
WKODM-2 15PPM BILGE WATER ALARM SYSTEM |
|
 |
WKODM-2 15PPM BILGE WATER ALARM SYSTEM |
|